OML18 – CAWTHORNE CHANNEL 1 - PD METERS INSPECTION REPORT

LOCATION: CAWTHORNE 1

The purpose of this inspection was to assess the Positive Displacement meters, identify potential issues/challenges with the flow meters, and recommend necessary repairs or upgrades to ensure safe and efficient operation.

Scope: The inspection covered the Technical Scope of Work for PD Meter Maintenance Including:

  • Overhaul and Servicing of the PD meter
  • Replacement of PDmeter parts
  • Proving the PD meter in accordance to NUPRC & API Standard
  • Re-certification of the PDmeter
PD Meter at CC1
Hook up point for meter Proving
2. OML18 – CAWTHORNE CHANNEL 2 - PD METERS INSPECTION REPORT
Metering Skid
ALAKIRI Metering skid
3. OML18 – CAWTHORNE CHANNEL 3 - PD METERS INSPECTION REPORT
CAWTHORNE 3 METERING SKID
Hook up point
PD METER AT CC3
4. OML18 – BILLE - PD METERS INSPECTION REPORT
BILLE METERING SKID
HOOK UP POINT
5. OML18 – ALAKIRI - PD METERS INSPECTION REPORT
Alakiri Prover Loop
ALAKIRI Metering skid
Additional Alakiri Metering Skid